Model
67 and B67 Series
The Models 67 and B67 are automatic
draining, frost proof wall hydrants with backflow protection. . Model B67 is enclosed in a
flush mounted wall box. Models HC67 & HCB67
provide a Hot and Cold Mixer. Hydrants drain as handle is shut off, even if hose is
attached. To close and drain hydrant, turn key clockwise until seated and water
drains out of opening, or hydrant may freeze and burst.
 |
|
Specifications
|
| HOSE CONNECTION BACKFLOW PREVENTER -
NIDEL Model 37HA with ¾ inch male hose thread, ASSE
Standard 1052 approved, UPC/ IAPMOâ listed, Field Testable, Two
check valves |
| MODEL 67 Conforms to ASME / ANSI A112.21.3M and the
hose coupling threads conform to ASME / ANSI B1.20.7 and ASME / ANSI B1.21M |
| EXTERIOR FINISH Standard Chrome;
Optional: Polished brass or brass; Other Options: Anodized Aluminum Box |
| MODULAR INSTALLATION 67 fits one
standard modular brick course, B67 fits two standard modular brick courses or one course
of facing tile. |
| VALVE SEAT - Permanent type
brass valve body with hemispherical seating surface. |
| VALVE - One piece valve
plunger accurately controls both flow and drainage with a minimum number of turns and
without need for adjustments |
| DRAIN Under nozzle away from
hands of operator and 67 offers a lip to divert water away from building |
| CASING - Copper tubes |
| NO LEAD SOLDER - All solder joints. |
| STEM - Hardened Stainless
Steel stem resists damage. |
| TEE KEY - Loose key operates
hydrant |
| OPERATING ROD - 3/8"
solid brass operating rod |
| WALL CLAMP Standard except close
coupled. |
| MAX PRESSURE 125 psi |
| MAX TEMP - 120° F |
|
This product is tested and listed to an ASSE standard.
The standard states that this product is not intended to be used for
continuous use |